pine64-rockpro64: add fancontrol
rk3399's operating temps are -20 to 80°C. It has sensors for CPU and GPU. The MINSTART/-STOP values are a result of empirical testing.
This commit is contained in:
parent
80d98a7d55
commit
f40197be9a
|
@ -6,4 +6,25 @@
|
||||||
"pcie_rockchip_host"
|
"pcie_rockchip_host"
|
||||||
"phy_rockchip_pcie"
|
"phy_rockchip_pcie"
|
||||||
];
|
];
|
||||||
|
# control the fan on the rockpro64 (like the one in the NAS case)
|
||||||
|
hardware.fancontrol = {
|
||||||
|
enable = lib.mkDefault true;
|
||||||
|
config = lib.mkDefault ''
|
||||||
|
INTERVAL=3
|
||||||
|
DEVPATH=hwmon0=devices/virtual/thermal/thermal_zone0 hwmon1=devices/virtual/thermal/thermal_zone1 hwmon3=devices/platform/pwm-fan
|
||||||
|
DEVNAME=hwmon0=cpu_thermal hwmon1=gpu_thermal hwmon3=pwmfan
|
||||||
|
# There can only be one sensor mapped to one pwm:
|
||||||
|
# https://github.com/lm-sensors/lm-sensors/issues/228
|
||||||
|
# Therefore you'll have to decide if you want to check CPU or GPU
|
||||||
|
# temps. If you want to use GPU instead, replace hwmon0 with
|
||||||
|
# hwmon1 below.
|
||||||
|
FCTEMPS=hwmon3/pwm1=hwmon0/temp1_input
|
||||||
|
MINTEMP=hwmon3/pwm1=40
|
||||||
|
MAXTEMP=hwmon3/pwm1=80
|
||||||
|
MINSTART=hwmon3/pwm1=35
|
||||||
|
MINSTOP=hwmon3/pwm1=30
|
||||||
|
MINPWM=hwmon3/pwm1=0
|
||||||
|
MAXPWM=hwmon3/pwm1=255
|
||||||
|
'';
|
||||||
|
};
|
||||||
}
|
}
|
||||||
|
|
Loading…